Product Details:
Payment & Shipping Terms:
|
Model: | ASli | Temperature: | -70°C ~+150°C(200 °C Optional) |
---|---|---|---|
Humidity: | 20%~98%R.H (5%~98%R.H Optional) | Temp. Analytic Accuracy: | 0.1°C |
Temp. Distribution Uniformity: | +/-2.0°C | Humi.analytic Accuracy: | 0.1% R.H |
Humi.distribution Uniformity: | +/- 3.0% R.H | Temp. Rising Rate: | 3.0°C/min (customized) |
Temp.Falling Rate: | 1.2°C/min(customized) | Material: | SUS 304# Stainless Steel |
Compressor: | French Tecumseh, Germany | Power: | 220V / 380V |
High Light: | temperature and humidity chamber,temperature and humidity test chamber |
PV solar modules testing instrument temperature and humidity
test chamber for lab use
Brief Introduction for PV Modules test standards
The designed usage time for solar cell module is about 20~30years , and the reliability test is the simulation of the earth's surface photovoltaic modules (crystalline silicon and amorphous silicon thin film, concentrating) design verification, can let the module long-term operating more than 20 years in a general climate , specification requires that solar cells module do test below :
Thermal cycle test;
Humidity-freeze test;
Damp Heat;
To confirm the solar cell can withstand high temperature and high humidity level with the minus temperature influence, as well as for repeated change caused by the temperature and thermal fatigue failure, in addition to determine solar cells resistant to moisture long-term penetration ability of the test equipment design and ability to meet the relevant standards below:
(IEC61646 , IEC61416 ,IEC61215 , UL1703 , IEC62108 , IEEE1513 ,IEC61730 etc ) .
Related Standard
IEC61215, IEC61646, IEC62108
UL1703, GB9535, GB18911 Test A: Damp-heat (3000H)
IEC61215, IEC61646, IEC62108,
UL1703, GB9535, GB18911 Test B : Humidity-Freeze Test (400H)
IEC61215, IEC61646, IEC62108,
UL1703, GB9535, GB18911 Test C: Thermal Cycling (1200H)
Silicon Solar Energy :IEC61215, UL1703 , GB9535
Thin Film Solar Cell:IEC61646, GB18911
Concentrating Solar Power :IEC62108 , IEEE1513
Damp Heat :
Condition :temperature 90 ±2 ℃ , humidity: 90% ±5% R.H.
Testing last for 1000h ,
P.S.: ASLi chamber can meet temperature 95 ±2 ℃ , humidity: 95% ±5% R.H.
Purpose:To determine the ability of the module to withstand the effects of long-term penetration of humidity.
Humidity-freeze test
Purpose:The purpose of this test is to determine the ability of the module to withstand the effects of high temperature and humidity followed by sub-zero temperatures. This is not a thermal shock test
Test points:low temperature -40℃,high temperature 85℃
Max temperature rising speed rate:200℃/Hour=3.33/min
Max temperature falling speed rate:200℃/Hour=3.33/min
24 hours per cycle,testing for 10 cycles, 240 hours(10 days)
Temp. Cycle Compare | High Temp. High Humidity | Low Temp | Temp. Change Rate | Cycle No. |
IEC61215 | 85℃/85±5%(20h) | -40℃(0.5~4h) | High Temp. Rise& Fall(100℃/h) Low Temp. Rise& Fall(200℃/h) |
10 |
GB9535 | 85℃/85±5%(20h) | -40℃(0.5~4h) | High Temp. Rise& Fall(100℃/h) Low Temp. Rise& Fall(200℃/h) |
10 |
IEC61646 | 85℃/85±5%(20h) | -40℃(0.5~4h) | High Temp. Rise& Fall(100℃/h) Low Temp. Rise& Fall(200℃/h) |
10 |
GB18911 | 85℃/85±5%(20h) | -40℃(0.5~4h) | High Temp. Rise& Fall(100℃/h) Low Temp. Rise& Fall(200℃/h) |
10 |
UL1703 | 85℃/85±2.5%(20h) | -40℃(0.5~4h) | High Temp. Rise& Fall(100℃/h) Low Temp. Rise& Fall(200℃/h) |
10 |
IEC62108 | 85℃/85±2.5%(20h) | -40℃(0.5~4h) | High Temp. Rise& Fall(100℃/h) Low Temp. Rise& Fall(200℃/h) |
20 40 |
Thermal cycle test;
Test points:low temperature :-40℃,high temperature:85℃
Temperature falling/rising speed rate:100℃/Hour=1.67℃/min
6 hours per cycle, testing last 50~200 cycles
Total testing time last 300 to 1200 hours (12.5 to 50 days )
Temp. Cycle Compare | Low Temp | High Temp | Temp Change Rate ℃/h | Dwell Time | Cycle No. |
IEC61215 | -40±2℃ | 85±2℃ | Max. 100℃/h | Min.10min | 50, 200 |
GB9535 | -40±2℃ | 85±2℃ | Max.100℃/h | Min.10min | 50, 200 |
IEC61646 | -40±2℃ | 85±2℃ | Max.100℃/h | Min.10min | 50, 200 |
GB18911 | -40±2℃ | 85±2℃ | Max.100℃/h | Min.10min | 50, 200 |
UL1703 | -40±2℃ | 90±2℃ | Max.120℃/h | 30~105min | 200 |
IEC62108 | -40±2℃ | 65℃,85℃,110℃ | 10cycle/day | 10min | 500,1000,2000 |
IEC62108 | -40℃ | 65℃,85℃,110℃ | 18cycle/day | 10min | 500,1000,2000 |
IEEE1513 | -40℃ | 90℃,110℃ | 0.9~7.5℃/min | Min.10min | 250,500 |
IEEE1513 | -40℃ | 90℃,110℃ | Max.100℃/h | Min.10min | 100,200 |
IEEE1513 | -40℃ | 60℃,90℃ | Max.100℃/h | Min.10min | 50,200 |
Contact Person: Doris
Tel: 0086-13602389184
Fax: 86-769-22851784
-70 to +150 Degree Climate Temperature Humidity Test Chamber Price
Walk-In Climate Test Chamber For Low High Temperature And Humidity Testing
HL-225-F High And Low Temperature Cycle Test Chamber Has Cyclical System
Walk-in Temperature Humidity Testing Room, Environmental Walk-in Chamber
Customized Walk In Climatic Test Chamber Environmental Test Equipment
20% - 98% Rh Walk In Climatic Stability Chamber Electronic For Auto Spare Parts
Sunshine Simulation Uv / Xenon Aging Room Walk In Stability Chamber For Color Fastness Test
Vertical Type Sine Shock Vibration Temperature Humidity Test Chamber
Electromagnetic Horizontal X / Y Axle vibration Test System 20 Kn Exiting Force
350000N Max Sine Force Vibration Measuring Instruments / Vibration Analysis Equipment
5 - 2000hz Vibration Test System 20kn Force With Vertical Horizontal Bench